The printer is showing the message "Check the print head thermistor wiring for possible damage."
Error name: Hotend mintemp error
Error code: #23208 (MK3.5)
This error is shown when the printer's nozzle temperature drops below 5 ºC at any point. If this happens during a print, the print will be stopped.
If the issue persists, the error likely stemmed from an issue with the hotend thermistor or, more rarely, hotend heater. To find out which one of these two is malfunctioning, perform the test described below.
Use a hairdryer to blow hot air towards the hotend. In the meantime, check if there is any temperature change on the LCD screen.