Tool offset out of bounds #17104 (XL)

Menu
Relevantní pro:
Poslední aktualizace a month ago
Tento článek je také dostupný v následujících jazycích: 
ENPLDEITFRJA

What happened?

On the multi-tool versions of the Original Prusa XL, the offset of the tools compared to the first is calibrated through the Tool Offset Calibration. If the offset of one of the tools deviates too far from the expected range, the printer will show the following message: "Tool %d offset %c: %.3f is out of bounds [%.3f, %.3f]".

In place of %d, the number of the tool is shown, in place of %c the axis, and in place of %3f the values. 

Error name: Tool offset out of bounds

Error code: #17104

How to fix it?

Filament unload

Make sure that the filament is unloaded before the calibration process. 

Nozzle position

Before proceeding further, make sure that the printer is FULLY COOLED DOWN AT ROOM TEMPERATURE, and OFF

On single-tool XL, after removing the x-carriage cover, hold the heater block (make sure that the nozzle is not heated!), and use the Torx TX8 key as shown in the picture to tighten the set screw. Do not use extra force while tightening, it may damage the hotend tube. The nozzle must be approximately at a 35°-40° angle to avoid damaging the hotend cables.

On multi-tool XL, identify the tool that has the nozzle to be checked, and park it. Hold the heater block (make sure that the nozzle is not heated!), and use the Torx TX8 key in the part shown in the picture to tighten the set screw. Do not use extra force while tightening, it may damage the hotend tube. The nozzle must be approximately at a 35°-40° angle to avoid damaging the hotend cables.

Nozzle cleaning

CAUTION: Heated parts can cause severe burns!
Check if the nozzle has residue. To clean it, heat the nozzle for three to five minutes at 250 °C, as the remains of the filament must be warmed up slightly so that they can be removed more easily. 

Use a small brass brush to clear away any old plastic stuck on the nozzle and heaterblock. Avoid contact of the brush with the hotend cables, as this could cause a short circuit.

Caution: the printer is still at a hot temperature! Wait until the hot parts are cooled down to ambient temperature. It takes approximately 10 minutes.

Swap the hotend

If the points above did not solve the issue, swap the hotend of the failing tool with one of the hotends from a tool that passes the calibration. 

Refer to the hotend replacement guide to swap the hotend from one tool to the other.

If the error moves with the hotend, please contact our customer support with this information.

Dock calibration

If the error message does not follow the tool where the hotend was swapped, it is possible that the issue derives from the dock or its calibration. 

Recalibrate the dock corresponding with the tool that displayed the error message. To do so, navigate to LCD Menu -> Control -> Calibrations & Tests -> Dock Position Calibration

Reduce vibrations

Any form of vibration propagated to the surface under the printer, or a not fully stable surface under the printer might cause a false reading on the loadcell, causing the homing error to trigger. 

For example, a printer that is in operation next to your Original Prusa XL can cause vibrations that are propagated to it, potentially causing a tool offset calibration fail. In that case, stop any printers next to your XL, and reattempt the calibration. 

A possible solution to dampening the noise and vibration of a printer is to add some additional padding underneath the printer. 

Byl tento článek užitečný?

Komentáře

Stále nemáte jasno?

Stále nemáte jasno?

Pokud nemůžete najít odpověď na vaši otázku, projděte si naše další materiály na webu.
A pokud nenajdete odpověď, pošlete nám zprávu na [email protected] nebo přes tlačítko níže.

Kontaktujte nás