UV calibration error #10319 (SL1)

Menu
Relevant for:
Last updated 4 years ago
This article is also available in following languages: 
ENCSPLDEESITFR

What happened?

The printer is displaying the message: Correct settings were found, but the standard deviation (found) is greater than the allowed value (allowed). Verify the UV LED calibrator's position and calibration, then try again.

Error name: UV calibration error

Error code: #10319

How to fix it?

The UV calibrator is detected but is receiving light in an unexpected range. It must lay flat on the display, positioned by the holes for the tank screws. Also, the orange cover should be closed.

Check the UV calibrator's connection and placement. If this is correct, and the UV LED panel or display is not giving any errors or is recently replaced, there may be an issue with the UV calibrator. Please, contact Customer support.