ES
  • English
  • Čeština
  • Italiano
  • Deutsch
  • Polski
  • Français
Iniciar sesión

4. Preparando el montaje

4. Preparando el montaje
Relevante para :
Ultima actualización 18 days ago
4. Preparando el montaje
 Dificultad
Fácil
 Pasos
6
 Idiomas disponibles
ENCSPLDEITFR
Attaching the MMU unit (part 1)
Attaching the MMU unit (part 1)
Attaching the MMU unit (part 1)
Attaching the MMU unit (part 1)
The MMU3 unit should be placed onto the top part of the printer's frame.
Place the MMU3 unit onto the frame.

Attach it just by the top hooks.
Look from behind, there are "clamps", which will be used to lock the unit to the frame in the next step.
Attaching the MMU unit (part 2)
Attaching the MMU unit (part 2)
Press the back part of the MMU3 unit downwards slightly, until the clamps lock to the frame.
Check that both bottom clamps on the unit are fully engaged.
If you need to remove the unit from the frame, simply lift the back part up to disengage the clamps.
MMU-to-Extruder PTFE tube
MMU-to-Extruder PTFE tube
Attach the PTFE tube onto the printer. One end goes onto the selector. The other goes onto the extruder. Tighten the fittings up using the Uniwrench.
Spoolholders setup
Spoolholders setup
The Buffer and spools setup in the picture is the one we will be trying to achieve. Arrange the spool holders and the buffer as seen in the picture.
Hook up the "printer holder" part on the buffer to the extrusion on the printer.
The PTFE tubes should go from the spoolholders to the buffer. Then, from the buffer to the back of the MMU.
Note the spool holder positioning. It is important that filament has as straight path as possible and that nothing interferes. PTFE tubes should not be bent too much. Otherwise, the filaments will jam.
Spoolholder-to-Buffer PTFE tube
Spoolholder-to-Buffer PTFE tube
Spoolholder-to-Buffer PTFE tube
Connect the PTFE tubes from the MMU unit to the BOTTOM row of collets on the buffer, ensuring you match the numbering on both the buffer and the MMU unit.
Attach each end of the PTFE tube from the Buffer to the PTFE holder on each Spool holder.
Make sure each spool holder is hooked up to the corresponding filament position number. (marked 1 to 5 on the MMU unit and the buffer.)
The MMU3 for MK4S necessitates the use of the latest version of the buffer components. If you're using an older version, it's essential to rebuild the device using the most recent version available.
Now it's time to get closer to printing. Let's move to the next chapter.
¿Fue útil esta guía?

Comentarios

¿Todavía tienes preguntas?

¿Todavía tienes preguntas?

Si tienes alguna pregunta sobre algo que no se ha tratado aquí, comprueba nuestros recursos adicionales.
Y si eso no lo soluciona, puedes enviar una petición a [email protected] o mediante el botón que hay más abajo.

Contacta con nosotros