Before it can align with any of the filament positions, the Idler inside the MMU unit needs to be “homed” to determine its position. First, the Idler moves to one end of the travel (endstop). Then, it moves to the other endstop, while measuring the angle between the end stops. The idler homes after the unit starts up has been reset or after another error occurred.
In case it can’t find the first homing endstop or the distance between the two endstops differs from the expected value, the printer will show an error.
Distance between the Idler endstops: 225 degrees
Allowed deviation: 10 degrees
The issue is usually mechanical. If you get this error, check the following items:
When using an unsupported, third-party hardware or a rare differently-sized version of the Idler motor from the MMU1 to MMU2 upgrade kits or the early batch of MMU2, later upgraded to MMU2S and finally to MMU3, you might need to tweak the sensitivity threshold of the StallGuard feature (Idler_sg_thrs_R). The current MK3S+ printer firmware allows you to Tune the threshold to a value between 4 and 7, directly from the error screen. If none of the values in this range help, you may need to set it to a value outside this range.
Some of these specific units might need to set the Idler sensitivity to a higher number such as 10.
You can do so by running a specific G-code command: M708 A0x19 X10. (where X10 denotes threshold value 10.) After that you can reset the MMU with: M709 command. Note that the commands are case-sensitive.
The command can be either run in a G-code file, or sent to the printer via USB connection, using a serial terminal app such as PuTTY.
For more info about the aforementioned commands, see the Registry MMU (MMU3) and the G-cody specifické pro Prusa Firmware articles.