Ultima actualización 5 months ago Este artículo está también disponible en los siguientes idiomas:
The Prusa Pro HT90 supports two print head configurations. The default high flow print head handles materials up to 300°C. For industrial materials like PEI, PEKK, and PEEK, use the high temperature print head, which reaches up to 500°C.
Removing print head
- Unload filament and cool the nozzle below 50°C.
- Turn off the printer and unplug it from power.
- Using a flat-head screwdriver, turn the stoppers by 120° counter-clockwise and remove them. Open the door to the maximum height.
![](https://cdn.help.prusa3d.com/wp-content/uploads/2024/09/89f309eade6c6a6a56ed8ec73845db92_painted.jpeg)
- At the top of the printer, behind the HEPA filter, there is a connector assembly held by a thumb screw. Undo the screw.
![](https://cdn.help.prusa3d.com/wp-content/uploads/2024/09/ae02e8af1c6375f33b8705f0d28d0378_painted.jpeg)
- Pull the entire connector assembly downwards to disconnect it.
![](https://cdn.help.prusa3d.com/wp-content/uploads/2024/09/000fa97f56002b8c9cbddb440b6b6375.jpg)
- Open the C-clamp holding the air hose and cable bundle.
![](https://cdn.help.prusa3d.com/wp-content/uploads/2024/09/dc2d28229b9ab0497205c497a7873568_painted.jpeg)
- Hold the print head with one hand and carefully disconnect the arms from the ball joints with your other hand, one by one. This will release the print head.
![](https://cdn.help.prusa3d.com/wp-content/uploads/2024/09/46a4536fb9cbe61c3d932ba9e5a73491_painted.jpeg)
- Remove the PTFE tube collet retainer clip.
![](https://cdn.help.prusa3d.com/wp-content/uploads/2024/09/68f84d171b860ca8a4e2839344787415_painted.jpeg)
- Push down the collet, while pulling the PTFE tube out, to remove it.
![](https://cdn.help.prusa3d.com/wp-content/uploads/2024/09/dd8f0fb4f45f242516fdf7b214fd5556_painted.jpeg)
Installing print head
- Lubricate the ball joints on the new print head with a small amount of PTFE lubricant.
- Connect the arms to the ball joints.
- Rejoin the C-clamp holder around the air tube and cable bundle.
- Insert the PTFE tube into the print head and secure the collet with the retainer clip.
- Reconnect the air hose and cable bundle behind the HEPA filter.
- Secure the connector assembly with the thumb screw.
- Close the cover and reinstall the cover stoppers.