What happened?

Implausible SuperFINDA sensor reading. This error occurs when the SuperFINDA sensor detects filament inside the Selector, but the MMU has no record of any filament being loaded. As a result, it cannot determine which filament position is loaded and cannot perform the unload automatically.

This often happens due to a malfunctioning or improperly calibrated SuperFINDA sensor.

Another potential cause could be if the filament was inserted into the selector manually, bypassing the menu/buttons, or restarting the printer during a load/unload operation before it was completed.

 

How to fix it?

  • Verify there is no filament in Selector and SuperFINDA sensor isn’t detecting a filament.
  • If filament is loaded, unload it manually or clear any obstructions triggering the SuperFINDA sensor.
  • Re-calibrate the SuperFINDA sensor.
    Also see the FINDA toubleshooting article.
  • Use only the menu on the printer to load or unload a filament during regular use. 